Limited-Time Offer: Enjoy 50% Savings! Coupon code: 50OFF Use it at checkout
Skip to content

Free VMware vSAN Specialist v2 5V0-22.23 Exam Questions

Last updated: · 13 practice questions with answers and explanations

Page: 1 / 8 Total 75 questions

Want more questions? Get Premium Access.

Question 1

New Single answer

Topic: Architecture and Technologies

Skill tested: Evaluates component placement and fault-domain requirements for vSAN fault tolerance.

A regional retailer is designing a four-host vSAN cluster. The hosts are split across two server rooms, and the design team wants a VM to remain available after any one room loses power. The rooms have independent power and networking, but the customer does not want to deploy a full stretched-cluster architecture or a witness appliance. The vSAN policy will use RAID-1 mirroring with one failure to tolerate. Which design decision best meets the availability requirement while preserving supported vSAN placement behavior?

Correct Answer: A. Configure each server room as a separate vSAN fault domain and place two hosts in each domain.
Explanation:

With two server-room fault domains, vSAN can place the two RAID-1 data components in different rooms, so loss of one room does not remove both copies. Fault domains aggregate hosts into failure groups; configuring each host separately would not express the room-level failure boundary. VM anti-affinity rules govern VM placement, not vSAN object-component placement. A stretched cluster requires a distinct witness role and is explicitly excluded by the requirements.

Question 2

New Multiple answers

Topic: Architecture and Technologies

Skill tested: Assesses ESA eligibility and networking considerations for a vSAN architecture decision.

An organization is refreshing a six-host vSAN cluster and wants to use the Express Storage Architecture (ESA). It plans to reuse the existing server model and NICs, but the storage team has not yet verified controller qualification or network capacity. The workload has a high write rate, and the design must use ESA-supported hardware and maintain predictable performance during resynchronization. Which two actions should the architect take before approving the design? Select TWO.

Correct Answer: D. Verify that the complete server and storage configuration is listed as supported for ESA in the applicable VMware Compatibility Guide.; E. Validate the supported network adapter configuration and provide sufficient vSAN network bandwidth for workload traffic and resynchronization.
Explanation:

ESA has specific hardware compatibility requirements; prior support for the Original Storage Architecture does not automatically qualify a server, controller, or drive configuration for ESA. The architect should validate the complete proposed configuration against the applicable Compatibility Guide and assess the vSAN network design, including bandwidth for normal I/O and resynchronization. ESA does not use OSA disk groups with separate cache devices, and deduplication and compression are not mandatory for ESA.

Question 3

New Single answer

Topic: Products and Solutions

Skill tested: Evaluates integration requirements for a Kubernetes storage solution using vSAN-backed persistent volumes.

A platform team will deploy Kubernetes on a vSphere environment and wants dynamically provisioned persistent volumes stored on an existing vSAN datastore. The Kubernetes control plane must request storage through supported vSphere integrations, while the vSphere administrators retain policy-based control over storage placement and protection. The team does not require an external storage array or a separate data-persistence platform. Which approach is most appropriate?

Correct Answer: C. Use vSphere with Tanzu or the supported vSphere Container Storage Interface integration to provision volumes backed by vSAN storage policies.
Explanation:

The supported vSphere Kubernetes storage integration can dynamically provision persistent volumes and use vSphere storage policies to control their backing storage, including vSAN. This preserves vSphere-side policy and lifecycle management. Kubernetes nodes do not directly create VMFS volumes on the vSAN datastore, and HCI Mesh presents a remote vSAN datastore to another vSphere cluster rather than exposing objects as file shares. vSAN Direct is intended for eligible local devices and is not a general substitute for policy-backed vSAN storage.

Question 4

New Single answer

Topic: Planning and Designing

Skill tested: Assesses vSAN capacity sizing for failures, policy overhead, and operational slack space.

A design team is sizing a six-host cluster for production VMs using RAID-1 with one failure to tolerate. Current usable VM data is expected to reach 40 TB, and the forecast includes 20 percent growth over three years. The business requires the cluster to continue operating through one host failure and needs capacity for resynchronization and routine maintenance. The team proposes sizing exactly to the projected mirrored data footprint because the cluster has six hosts. What is the best design response?

Correct Answer: B. Model policy overhead and growth, then reserve additional capacity for host-failure rebuilds, resynchronization, and operational slack rather than targeting full utilization.
Explanation:

A robust design accounts for the actual storage policy overhead, forecast growth, and the capacity needed to restore protection after a failure. It also retains operational slack; sizing to the calculated data footprint alone can leave too little free space for resynchronization or maintenance. RAID-1 does not become capacity-neutral merely because multiple hosts exist. Compression is not automatic for every workload, and changing to an erasure-coding policy requires checking eligibility, workload characteristics, and the relevant architecture rather than assuming it is universally suitable.

Question 5

New Multiple answers

Topic: Planning and Designing

Skill tested: Evaluates HCI Mesh design choices for sharing vSAN capacity across clusters.

A company operates separate compute and storage vSAN clusters in the same vSphere environment. A new compute cluster is short on capacity, while the storage cluster has spare capacity and must remain independently managed. The organization wants compute VMs to consume storage from that cluster without adding storage devices to every compute host. Both clusters meet the applicable version and compatibility requirements, and the network between them is reliable. Which two design statements are correct? Select TWO.

Correct Answer: A. Remote vSAN datastore traffic and storage-cluster health become relevant dependencies for workloads running in the compute cluster.; D. HCI Mesh can let the compute cluster mount a remote vSAN datastore provided by the storage cluster.
Explanation:

HCI Mesh enables a vSAN cluster to consume a datastore exported by another vSAN cluster, allowing compute and storage resources to be scaled independently. The design must account for network connectivity and the availability and performance of the remote storage cluster because compute workloads depend on it. HCI Mesh does not merge clusters or their management and policy domains, does not require the storage cluster to be stretched, and is specifically intended to allow clients outside the datastore-providing cluster to consume its storage.

Question 6

New Single answer

Topic: Installing, Configuring, and Setup

Skill tested: Assesses storage-policy configuration for site-level protection in a stretched vSAN cluster.

A financial services company runs a vSAN stretched cluster with two data sites and a witness site. A critical VM must tolerate the complete loss of either data site, and the organization wants the VM's data to be protected across both sites. The cluster is healthy, and the VM currently uses the default storage policy. The administrators must configure protection through policy rather than relying on VM placement rules. Which policy change is most appropriate?

Correct Answer: B. Set the site disaster tolerance rule to Dual site mirroring, then set the required local protection within each site.
Explanation:

A stretched-cluster policy must specify site-level disaster tolerance. Dual site mirroring places data across the two data sites, while local protection settings determine protection within each site. A generic component failure setting or striping rule does not replace site-level protection. Force provisioning can allow policy noncompliance in some circumstances; it does not create the required site-protection layout and is not an appropriate substitute for configuring the policy correctly.

Question 7

New Single answer

Topic: Installing, Configuring, and Setup

Skill tested: Evaluates vSAN HCI Mesh client-cluster configuration and datastore mounting.

An administrator has completed the network and compatibility checks for a vSAN HCI Mesh deployment. The storage cluster has exported its vSAN datastore, and the compute cluster is intended to consume that capacity. The administrator is following the vSphere Client workflow and wants to avoid changing the storage cluster's membership or accidentally creating another local datastore. What should the administrator do next?

Correct Answer: D. From the client compute cluster, mount the remote vSAN datastore using the storage cluster as the datastore provider.
Explanation:

In an HCI Mesh configuration, the client cluster mounts the remote vSAN datastore offered by the storage cluster. This keeps the compute and storage clusters distinct and does not add remote capacity as a local disk group. Merging host membership changes the intended architecture, and remote datastores are not cache devices. Enabling File Services creates file shares, which is a different service and is not required for HCI Mesh datastore consumption.

Question 8

New Single answer

Topic: Performance-tuning, Optimization, and Upgrades

Skill tested: Assesses safe vSphere Lifecycle Manager remediation sequencing for a vSAN cluster.

A four-host vSAN cluster needs a planned ESXi patch. The vSphere Lifecycle Manager image is already validated, and the cluster has enough resources to run workloads on three hosts. The administrator wants to minimize risk to object availability and avoid starting remediation while resynchronization is active. Which action is the best next step before applying the patch?

Correct Answer: B. Check vSAN health and resynchronization status, then remediate hosts sequentially using the vLCM workflow with an appropriate maintenance-mode evacuation option.
Explanation:

Before remediation, administrators should confirm cluster health and ensure that resynchronization is not in progress. Sequential remediation allows the cluster to recover between hosts and helps preserve availability. The maintenance-mode data evacuation choice should match the protection and capacity requirements; selecting an option blindly can cause unnecessary movement or risk. Concurrent remediation can remove too many resources at once, while disabling vSAN is not a normal patching prerequisite and can disrupt storage availability.

Question 9

New Single answer

Topic: Performance-tuning, Optimization, and Upgrades

Skill tested: Evaluates vSAN component striping as a response to object-size and performance constraints.

A database VM has a large VMDK that is receiving concentrated I/O. Performance analysis shows that a single component's size is approaching the platform's supported limit, and the administrator has confirmed that the workload is not primarily limited by network latency or host CPU. The current policy does not require a change in failure tolerance or RAID layout. Which policy adjustment is most directly relevant to distribute the object across more components?

Correct Answer: B. Increase the number of disk stripes per object, then evaluate the resulting layout and resynchronization impact.
Explanation:

The disk-stripes-per-object policy rule can influence how an object is split across components, making it relevant when component size or distribution is the concern. The change should be validated against the workload and its resynchronization impact. Increasing failure tolerance changes protection requirements, not the intended striping setting. Force provisioning affects object creation under policy or resource constraints, and object-space reservation reserves capacity; neither is a component-striping control.

Question 10

New Multiple answers

Topic: Troubleshooting and Repairing

Skill tested: Interprets vSAN resynchronization state and distinguishes temporary durability components from permanent protection.

After a disk failure, Skyline Health reports resynchronization activity and a durability component for one object. The object remains accessible, but the operations team is considering deleting the component to free capacity. The cluster has not yet completed repair, and the failed device has not been replaced. Which two conclusions or actions are appropriate? Select TWO.

Correct Answer: D. Monitor resynchronization and object health, and allow repair to complete before assessing whether the object has returned to policy compliance.; E. Treat the durability component as a temporary protection mechanism associated with a repair or resynchronization operation, not as an orphan to delete.
Explanation:

A durability component helps preserve accessibility or protection during certain repair and resynchronization operations. Its presence does not mean that repair is complete or that the component is an unassociated object that can safely be removed. The correct operational response is to monitor resynchronization and object health, then verify compliance after repair. Deleting it or placing the remaining hosts in maintenance mode could undermine protection or prevent the repair from completing; Force provisioning does not resolve this condition.

Question 11

New Single answer

Topic: Troubleshooting and Repairing

Skill tested: Assesses capacity troubleshooting through storage-policy changes and object compliance verification.

A vSAN cluster is nearing full capacity, and several VMs are protected with RAID-1 policies requiring one failure to tolerate. No hardware failure is active, but administrators need temporary headroom for routine operations. The workloads are not all equally critical, and the organization permits a policy change for a subset of noncritical VMs after approval. What is the most appropriate approach?

Correct Answer: B. Identify eligible noncritical objects, apply a policy with lower capacity overhead where appropriate, and monitor policy compliance and resynchronization.
Explanation:

A carefully selected storage-policy change can reduce capacity overhead for eligible noncritical workloads, but the team must consider the resulting protection level and verify compliance and resynchronization. This is a controlled capacity-management measure, not a substitute for adding capacity when required. Force provisioning does not create capacity, witness components are not the source of mirrored data consumption, and a 100 percent reservation reserves capacity rather than reducing consumption.

Question 12

New Multiple answers

Topic: Administrative and Operational Task

Skill tested: Evaluates maintenance-mode evacuation choices against vSAN availability and capacity requirements.

An administrator must remove one host from a healthy vSAN cluster for an extended hardware replacement. The cluster has adequate capacity to evacuate the host's data, and the organization requires objects to remain protected and compliant during the work. The change window allows data movement to finish before the host is powered down. Which two actions or considerations are appropriate? Select TWO.

Correct Answer: C. Confirm available capacity and cluster health before migration, and monitor resynchronization until the objects are protected on remaining hosts.; D. Use Full data migration for the host's maintenance-mode entry, then verify that evacuation and resynchronization have completed.
Explanation:

Full data migration evacuates the host's data and is appropriate when capacity is available and maintaining protection during an extended removal is required. The administrator should verify health and capacity beforehand and wait for evacuation and resynchronization to finish. Ensure Accessibility prioritizes access and may leave objects noncompliant; it does not guarantee full protection. No data migration leaves components on the host, and disabling policies does not provide a sound availability strategy.

Question 13

New Single answer

Topic: Administrative and Operational Task

Skill tested: Assesses vSAN encryption-key dependency and recovery planning for secure data access.

A company has enabled vSAN data-at-rest encryption and stores its key-encryption keys in an external Key Management Server (KMS). During a planned KMS replacement, the security team proposes removing the old KMS immediately after configuring the new server. The vSAN cluster is healthy, and the team wants to preserve access to encrypted objects through the change. What should the administrator do?

Correct Answer: A. Verify the new KMS connectivity and trust configuration, ensure the required keys are available through the supported key-provider workflow, and only then retire the old KMS.
Explanation:

Encrypted vSAN data depends on access to the required keys through the configured key-provider arrangement. The new KMS or key provider must be reachable and correctly trusted, and the required keys must remain available before the old service is retired. Removing the old KMS prematurely can jeopardize access to encrypted data. Disabling encryption and recreating objects is unnecessary, while VM encryption also requires key management and is not a way to eliminate that dependency.