Limited-Time Offer: Enjoy 50% Savings! Coupon code: 50OFF Use it at checkout
Skip to content

Free NetApp Cisco and NetApp FlexPod Design Specialist NS0-175 Exam Questions

Last updated: · 11 practice questions with answers and explanations

Page: 1 / 6 Total 60 questions

Want more questions? Get Premium Access.

Question 1

New Single answer

Topic: Information Gathering for FlexPod Solutions

Skill tested: Identify FlexPod architecture components and their roles during solution discovery.

A healthcare organization is evaluating a FlexPod design for a new clinical application. The discovery team has documented the required compute capacity, storage performance, and redundant network paths, but the application owner assumes that FlexPod is a single integrated appliance delivered with one fixed hardware configuration. The organization needs to understand which elements form the solution before requesting a validated design. Which description best explains the principal FlexPod components and their relationship?

Correct Answer: C. Cisco UCS compute and Cisco networking are combined with NetApp storage and managed as a validated, flexible infrastructure architecture.
Explanation:

FlexPod is a validated infrastructure architecture that combines Cisco compute and networking with NetApp storage. The components remain identifiable systems, but their design and interoperability are validated together; FlexPod is not necessarily a single fixed appliance. Cisco UCS supplies the compute platform, Cisco switches provide network connectivity, and NetApp systems provide storage services. The other descriptions either misassign product roles, incorrectly impose a fixed bundle or cloud-only storage requirement, or omit the networking component that connects the solution.

Question 2

New Multiple answers

Topic: FlexPod Design

Skill tested: Select appropriate NetApp storage capabilities for a FlexPod solution's availability and protocol needs.

A financial services company is designing a FlexPod platform for a transaction application and its virtualized infrastructure. The application requires block access over a redundant SAN, while virtual machine datastores and file shares require NAS access. The storage design must tolerate a controller failure without relying on a second storage system at another site. Which two storage design choices best satisfy these requirements? Select TWO.

Correct Answer: C. Use an ONTAP platform that supports the required SAN and NAS protocols, with storage configured for the application's access requirements.; E. Use a high-availability controller pair and configure appropriate block and NAS data access.
Explanation:

An ONTAP storage system can provide supported block and NAS access for workloads with different protocol needs, and a high-availability controller pair addresses local controller failure. Both choices together match the requirement for SAN block access, NAS services, and local storage availability. A SAN fabric cannot take over for a failed storage controller, so a single-controller design does not meet the resilience requirement. NFS is not a substitute for the required block protocol, and a remote storage system is not necessary to provide local controller resilience.

Question 3

New Single answer

Topic: FlexPod Design

Skill tested: Choose Cisco UCS compute and networking architecture for redundant server connectivity.

An enterprise is expanding an existing FlexPod design with Cisco UCS B-Series blade servers. It requires centralized server policy management and redundant paths from each server to the network and storage fabrics. The team wants to retain the UCS domain model rather than deploy standalone rack servers with separate per-server configuration. Which design approach best fits these requirements?

Correct Answer: A. Use Cisco UCS Fabric Interconnects to provide the UCS domain's management and fabric connectivity, with redundant paths from the chassis.
Explanation:

Cisco UCS Fabric Interconnects provide the UCS domain management and fabric connectivity for attached blade chassis, supporting centralized policy-based management and redundant connectivity when designed with appropriate paths. Directly managing each blade independently conflicts with the stated UCS domain model. A single Fabric Interconnect creates a single point of failure, and storage multipathing cannot replace redundant server network connectivity. NetApp storage controllers do not serve as the management plane for UCS compute.

Question 4

New Single answer

Topic: FlexPod Configuration

Skill tested: Configure UCS virtual interfaces and VLAN connectivity for a FlexPod network.

During implementation of a FlexPod UCS domain, an administrator creates a service profile for a server that needs separate Ethernet connectivity for management and application traffic. Both networks must traverse the UCS fabric and reach the appropriate upstream VLANs. No physical adapter change is planned, and the design uses virtual network interfaces presented by the fabric. What is the most appropriate configuration step?

Correct Answer: B. Create the required VLANs in the UCS domain, define Ethernet vNICs in the service profile, and associate them with the intended fabric and VLAN policies.
Explanation:

UCS Ethernet vNICs are defined through the service profile and associated with the appropriate fabric and VLAN configuration. The VLANs must also be available through the UCS networking configuration and upstream network so traffic can reach its destination. Assigning each blade a direct physical uplink bypasses the intended UCS fabric model. vHBAs carry Fibre Channel traffic, not ordinary management and application Ethernet traffic, and configuring storage interfaces alone cannot establish the server's UCS Ethernet connectivity.

Question 5

New Multiple answers

Topic: FlexPod Configuration

Skill tested: Implement SAN boot with UCS service profiles, boot policies, and storage LUN mapping.

A company is deploying stateless UCS servers in a FlexPod environment. It wants each server to boot from a SAN LUN so that replacement hardware can inherit the server identity and boot configuration through its service profile. The boot LUNs are presented through a redundant Fibre Channel fabric. Which two configuration actions are required for this design? Select TWO.

Correct Answer: A. Ensure the server's Fibre Channel connectivity and initiator identity are correctly configured, and present the boot LUN to the relevant initiators.; C. Configure a SAN boot policy with the required target and LUN information and associate it with the service profile.
Explanation:

A UCS SAN boot policy defines the boot target and LUN information, and associating it with the service profile makes that boot configuration part of the server's policy. The server must also have working Fibre Channel paths and initiator identities, while the storage must present the boot LUN to those initiators. Local disk-only boot defeats the SAN-boot goal. Ethernet VLANs and management IP addresses do not replace Fibre Channel storage connectivity, zoning, or LUN presentation.

Question 6

New Single answer

Topic: FlexPod Configuration

Skill tested: Configure ONTAP storage objects and host access for a FlexPod workload.

A FlexPod administrator must provision block storage for a newly installed application host. The host is connected to the designated SAN fabric, and the storage team has collected its initiator identifiers. The implementation must provide an isolated storage container, a block LUN, and access only to the intended host group. Which sequence best reflects the storage-side configuration?

Correct Answer: A. Create the appropriate storage virtual machine and SAN LIFs, create a LUN, map it to an initiator group containing the host initiators, and verify fabric connectivity.
Explanation:

For SAN block access, the storage virtual machine provides the storage context and SAN interfaces, the LUN supplies the block device, and an initiator group controls which host initiators may access it. The host's Fibre Channel path and fabric configuration must also be valid. An export policy is for NAS access, not mapping Fibre Channel initiators to a LUN. A host-local volume or UCS VLAN does not provision a shared SAN LUN, and broad mapping to every data-center initiator violates least privilege.

Question 7

New Single answer

Topic: FlexPod Configuration

Skill tested: Apply Cisco Nexus switch configuration principles for redundant FlexPod connectivity.

A network engineer is bringing a pair of Cisco Nexus switches into service for a FlexPod deployment. The design requires the switches to provide redundant connectivity while preserving the intended separation of management, server, and storage traffic. The engineer proposes placing every connected interface into one VLAN and relying on redundant cabling to provide traffic isolation. Which approach is most appropriate?

Correct Answer: B. Use the documented FlexPod network design, configure the required VLANs and interface roles, and implement the validated inter-switch and upstream connectivity.
Explanation:

The Nexus configuration should implement the planned traffic separation, interface roles, and redundant connectivity appropriate to the FlexPod design. VLAN segmentation is a logical configuration requirement; redundant cables alone do not isolate management, server, and storage traffic. A single shared VLAN therefore fails the stated separation requirement. Removing inter-switch connectivity or leaving interfaces without deliberate VLAN and role configuration can prevent expected paths and makes the design difficult to operate consistently.

Question 8

New Single answer

Topic: FlexPod Administration

Skill tested: Use FlexPod management tools and documentation for lifecycle and configuration visibility.

An operations team manages several FlexPod deployments with different hardware generations. During an audit, engineers need a reliable record of each system's components, software versions, configuration state, and applicable validated design guidance. They also need to plan future changes without assuming that every configuration is supported merely because the products can connect. What is the best operational practice?

Correct Answer: C. Maintain an accurate inventory and configuration record, and use the applicable NetApp and Cisco FlexPod documentation and validation guidance when evaluating changes.
Explanation:

FlexPod administration depends on knowing the deployed components and versions, then using the relevant validated design and vendor guidance to assess operations and changes. An inventory and configuration record supports troubleshooting, lifecycle planning, and auditability. Product-to-product connectivity alone does not establish that a configuration is validated. No single management tool eliminates all vendor-specific management needs, and software versions can materially affect interoperability and supported configurations.

Question 9

New Multiple answers

Topic: FlexPod Administration

Skill tested: Plan FlexPod upgrades using validated compatibility information and staged change controls.

A platform team plans an upgrade to a FlexPod environment, but the deployment spans UCS, Nexus, and ONTAP components and supports a business-critical application. The change window is short, and rollback must be practical if validation fails. The team proposes upgrading all components at once to minimize maintenance windows. Which two actions provide the soundest lifecycle approach? Select TWO.

Correct Answer: B. Develop a component-aware upgrade sequence and rollback plan, then validate connectivity and workload function at appropriate stages.; E. Check the applicable FlexPod validated design and product compatibility guidance for the exact deployed and target versions before scheduling the change.
Explanation:

FlexPod lifecycle changes should be planned against the applicable validated design and compatibility guidance, using the exact component versions in scope. A staged, component-aware sequence with rollback provisions and validation limits exposure and helps isolate failures. Upgrading everything simultaneously does not remove interoperability risk and makes fault isolation harder. Deferring compatibility checks shifts avoidable risk into the maintenance window, while UCS and Nexus changes can affect workload connectivity and therefore cannot be ignored.

Question 10

New Single answer

Topic: FlexPod Troubleshooting

Skill tested: Diagnose SAN boot failures by isolating UCS, fabric, and storage presentation dependencies.

After a maintenance change, several UCS servers fail to boot from their SAN LUNs. Their service profiles remain associated, and the servers can see their adapters, but the boot process reports that no bootable target is available. Other workloads using the storage system continue to operate. The team must identify the fault domain before changing the storage configuration broadly. What should the engineer do FIRST?

Correct Answer: A. Verify the affected servers' SAN boot policy, Fibre Channel path and zoning, and whether the boot LUN remains mapped to their initiators.
Explanation:

The symptoms localize the issue to dependencies in the SAN boot path: the UCS boot policy and target details, Fibre Channel connectivity and zoning, and storage-side LUN presentation. Checking these elements first identifies whether the maintenance change affected the server configuration, fabric path, or initiator mapping. Healthy storage workloads make a wholesale controller replacement or recreation of storage objects unjustified. Switching to local boot changes the design rather than diagnosing the failure and could prevent the intended stateless recovery model.

Question 11

New Multiple answers

Topic: FlexPod Troubleshooting

Skill tested: Isolate Ethernet reachability faults across UCS vNIC, VLAN, and Nexus switch configuration.

A newly provisioned UCS server can reach its management network but cannot communicate with its application subnet. The application VLAN is configured upstream on the Nexus pair, and the server's service profile contains a vNIC intended to carry that VLAN. Peer servers on the same subnet remain reachable. The team wants to troubleshoot without disrupting the management path or making broad switch changes. Which two checks should be performed first? Select TWO.

Correct Answer: C. Confirm that the application VLAN is defined and allowed on the UCS vNIC and relevant fabric uplinks.; E. Verify the affected vNIC's fabric association and that its upstream path reaches the intended Nexus VLAN configuration.
Explanation:

Because management works and peer systems are reachable, the first checks should focus on the affected server's application vNIC and VLAN path. Confirming VLAN membership and allowance in the UCS configuration, and tracing the vNIC's fabric association through the uplinks to the Nexus VLAN configuration, can reveal a missing or mismatched network assignment without disturbing management connectivity. Resetting switch ports or removing the management VLAN is unnecessarily disruptive. Storage LUN mapping does not explain Ethernet subnet reachability, and disabling management does not correct the application VLAN path.