Limited-Time Offer: Enjoy 50% Savings! Coupon code: 50OFF Use it at checkout
Skip to content

Free Oracle Database 19c: Data Guard Administration 1Z0-076 Exam Questions

Last updated: · 13 practice questions with answers and explanations

Page: 1 / 11 Total 107 questions

Want more questions? Get Premium Access.

Question 1

New Single answer

Topic: Oracle Data Guard Basics

Skill tested: Selects a Data Guard standby type that supports temporary testing without changing the production database.

A retailer wants to run a two-day upgrade rehearsal against a recent copy of its production database. The test must permit application writes and DDL, while the production primary remains available and the copy can later return to a synchronized standby without rebuilding it. The DBA has a physical standby with sufficient storage and can tolerate suspending redo apply during the rehearsal. The test data must not become part of the production database. Which design best meets these requirements?

Correct Answer: B. Convert the physical standby to a snapshot standby, perform the rehearsal, then convert it back to a physical standby.
Explanation:

A snapshot standby opens read/write for temporary testing while preserving the redo received from the primary. On conversion back to a physical standby, Oracle discards the local updates made during the snapshot period and applies the accumulated redo. Opening a physical standby read/write while managed recovery continues is not the supported method. A logical standby has different SQL Apply characteristics and does not provide this simple discard-and-resynchronize workflow. An Active Data Guard real-time query standby is read-only, so it cannot support the required general application writes.

Question 2

New Single answer

Topic: Managing Oracle Net Services in a Data Guard Environment

Skill tested: Designs Oracle Net connect descriptors that support role transitions and redo transport.

A company operates a primary and physical standby in separate data centers. The standby may become primary during a switchover or failover, and the operations team wants redo transport to reconnect to whichever database currently has the primary role. Each database has a static service name registered in Oracle Net, and the network team requires the redo destination configuration to remain identical on both systems. Which approach is most appropriate?

Correct Answer: C. Use a role-based service that is available only when the database has the PRIMARY role, and use the same connect identifier for the redo destination on both databases.
Explanation:

A role-based service can be started on the database that currently performs the primary role, allowing a consistent Oracle Net connect identifier to target the correct database after role transitions. This supports symmetric redo transport configuration and avoids manual edits to host-specific destinations. A unique service for each host requires operational changes after a transition. A listener does not infer and redirect a connection based solely on database role, and routing through the standby's listener does not make it a transparent primary-role service.

Question 3

New Multiple answers

Topic: Creating a Physical Standby Database by Using SQL and RMAN Commands

Skill tested: Prepares a primary database and RMAN duplicate workflow for active physical standby creation.

A DBA must create a physical standby from an open Oracle Database 19c primary by using RMAN active duplication. The primary uses a recovery area, and the standby will have a different directory layout. There is no pre-existing standby backup. The network path supports the required Oracle Net connections, and the DBA wants the duplicate to recover using redo from the primary after the copy is made. Which two actions are appropriate? Select two.

Correct Answer: B. Run RMAN DUPLICATE TARGET DATABASE FOR STANDBY FROM ACTIVE DATABASE with an appropriate filename-conversion or OMF configuration for the standby.; D. Enable forced logging on the primary and configure the required standby redo logs and a valid remote redo transport destination.
Explanation:

Forced logging helps ensure that database changes are represented in redo, while standby redo logs and a functioning remote destination support redo transport and subsequent real-time recovery. RMAN active duplication can create the standby directly from the open primary; the command and file-name handling must account for the standby's layout. Disabling archiving undermines recoverability. The duplicate operation creates and configures the standby control file, so opening it with RESETLOGS beforehand is inappropriate. The primary and standby require distinct DB_UNIQUE_NAME values.

Question 4

New Single answer

Topic: Using Oracle Active Data Guard: Supported Workloads in Read-Only Standby Databases

Skill tested: Identifies supported read-only standby workloads and the effect of real-time query on redo apply.

A reporting group runs long-running queries against a physical standby while the business requires the standby to remain current with incoming redo. The database is licensed and configured for Active Data Guard, and the standby has standby redo logs. Some reports use temporary tables and local temporary segments; the team does not need to update permanent application tables. Which operating approach best satisfies the requirements?

Correct Answer: D. Open the standby read-only with the appropriate real-time query mode so Redo Apply can use redo in standby redo logs while reports run.
Explanation:

With Active Data Guard real-time query, a physical standby can be open read-only while Redo Apply continues, including use of redo as it arrives in standby redo logs. This supports reporting without turning the database into a writable copy. Opening read-only without the real-time query capability does not provide the required concurrent apply behavior. A physical standby cannot be made a general read/write database while Redo Apply continues. Repeated snapshot conversions suspend apply and are unnecessary for read-only reporting.

Question 5

New Multiple answers

Topic: Creating and Managing a Snapshot Standby Database

Skill tested: Chooses broker-managed conversion steps for a writable snapshot standby and its later restoration.

An engineering team needs a writable copy of a physical standby for a short application compatibility test. The Data Guard Broker manages the configuration, and the standby has a guaranteed restore point capability available through the snapshot standby conversion workflow. Redo must continue to arrive from the primary during the test, but it need not be applied until the test ends. The tested changes must be discarded, after which the standby must resume normal recovery. Which two actions should the DBA take? Select two.

Correct Answer: C. After testing, use DGMGRL to convert the snapshot standby back to a physical standby so local test changes are discarded and redo apply resumes.; D. Use DGMGRL to convert the physical standby to a snapshot standby, then open it read/write for the test.
Explanation:

Broker-managed conversion to a snapshot standby provides the supported writable test environment. Redo can continue to be transported to the snapshot standby, although it is not applied while the database is in that role. Converting back to a physical standby discards changes made locally during the snapshot period and resumes redo apply. Stopping transport and deleting required archived redo is unnecessary and risks recovery gaps. A physical standby is not opened read/write this way, and a logical standby does not automatically isolate arbitrary test transactions.

Question 6

New Single answer

Topic: Creating a Logical Standby Database

Skill tested: Selects logical standby creation when SQL transformations and open read/write access are required.

A financial services organization wants a reporting database that stays synchronized with its primary but must exclude selected sensitive tables and permit approved local schema changes. The reporting database must remain open for read and write access to its own application objects while SQL Apply processes supported primary changes. The DBA has verified that the primary workload and required objects are supported by logical standby. Which standby type is the best fit?

Correct Answer: B. Logical standby, because SQL Apply maintains logical changes while allowing supported local access and filtering.
Explanation:

A logical standby uses SQL Apply to transform and apply supported changes from the primary and can remain open for read/write activity, subject to logical standby restrictions. It also supports filtering of selected objects, making it a plausible fit for reporting and controlled local changes. A physical standby uses Redo Apply and is not a general read/write reporting database while applying redo. A snapshot standby is temporarily writable but does not selectively exclude primary tables as a permanent reporting design. A far sync instance only receives and forwards redo; it is not a reporting database.

Question 7

New Multiple answers

Topic: Managing Physical Standby Files After Structural Changes on the Primary Database

Skill tested: Determines when standby file-management settings handle primary-side datafile additions automatically.

After a primary database administrator adds a tablespace, a physical standby reports that the new datafile cannot be created at the expected location. The standby uses a different filesystem layout from the primary. The DBA wants future primary-side datafile additions to be created automatically on the standby without routine manual file creation, and the standby is configured to manage standby files through database parameters. Which two checks or actions are appropriate? Select two.

Correct Answer: C. Verify that standby file management is set to AUTO so Oracle can create corresponding standby datafiles.; D. Configure DB_FILE_NAME_CONVERT appropriately for the differing primary and standby file naming patterns, or use a suitable OMF-based layout.
Explanation:

With STANDBY_FILE_MANAGEMENT set to AUTO, Oracle can create standby datafiles in response to primary-side additions, provided it can determine suitable standby names. Different filesystem layouts require correct DB_FILE_NAME_CONVERT mappings or an appropriate Oracle Managed Files configuration. MANUAL disables this automatic file-management behavior rather than enabling it. DB_UNIQUE_NAME values should distinguish the databases and do not map filenames. Routine recovery suspension and manual creation are unnecessary when automatic file management is correctly configured.

Question 8

New Single answer

Topic: Oracle Data Guard Broker Basics

Skill tested: Distinguishes broker configuration, database, and observer roles in a managed Data Guard environment.

A company is reviewing its Data Guard control plane before enabling fast-start failover. Administrators currently issue SQL commands directly on each database and want centralized role-transition management, configuration health checks, and an external observer for automated failover decisions. They need to understand which component performs each responsibility before implementation. Which description is accurate?

Correct Answer: D. The broker configuration is a collection of databases and related settings; DGMGRL or Enterprise Manager manages it, while an observer monitors the configuration for fast-start failover.
Explanation:

The broker manages a configuration comprising the primary, standby databases, and associated properties. Administrators can interact with it through DGMGRL or Enterprise Manager. An observer is a separate process used with fast-start failover to monitor the broker configuration and participate in the failover decision; it does not store or apply redo. Broker management is not limited to the primary, and an observer is not required for an ordinary manual switchover.

Question 9

New Single answer

Topic: Monitoring a Data Guard Broker Configuration

Skill tested: Uses broker validation commands to diagnose readiness before a planned role transition.

Before a planned switchover, a DBA sees that the broker configuration reports success but wants a more specific check that each database is suitably configured for the transition. The team uses DGMGRL and wants to identify configuration, database, and network issues before committing to the role change. They are not asking for a general status display or an actual switchover. Which command approach is most appropriate?

Correct Answer: A. Run VALIDATE DATABASE for the relevant databases and VALIDATE NETWORK CONFIGURATION to check connectivity before the switchover.
Explanation:

Broker VALIDATE commands provide targeted checks beyond a simple status summary. VALIDATE DATABASE can assess readiness of a database for role transitions, while VALIDATE NETWORK CONFIGURATION checks connectivity between configuration members. SHOW CONFIGURATION is useful for status but is not a substitute for these validations. Changing protection mode addresses a different configuration property, and initiating a switchover before completing readiness checks reverses the safe operational sequence.

Question 10

New Multiple answers

Topic: Configuring Data Protection Modes

Skill tested: Matches Data Guard protection mode and transport method to zero-loss and availability requirements.

A payment processor requires zero data loss for a local standby when it is available, but it also requires the primary to remain available if the standby becomes unreachable. The primary and standby are connected by a low-latency network, and the standby has standby redo logs. The organization accepts that protection may be reduced during a standby outage rather than having primary transactions block indefinitely. Which two configuration choices best match this policy? Select two.

Correct Answer: A. Use Maximum Availability protection mode with synchronous redo transport to the standby.; D. Configure the synchronous destination with an appropriate NET_TIMEOUT and an alternate asynchronous destination or other planned fallback behavior for loss of the preferred standby.
Explanation:

Maximum Availability with synchronous transport provides zero-data-loss protection while the standby is available, while allowing the primary to continue after a prolonged communication failure with a temporary reduction in protection. A suitable timeout and planned alternate behavior help manage destination failures. Maximum Protection can shut down the primary if it cannot write redo to a required synchronous destination, conflicting with the availability constraint. Maximum Performance normally uses asynchronous transport and can lose committed transactions during a failure. The protection-mode name does not make asynchronous transport lossless.

Question 11

New Single answer

Topic: Performing Role Transitions

Skill tested: Selects a broker switchover procedure that preserves a planned, synchronized role transition.

A maintenance window requires the current primary and physical standby to exchange roles with no data loss. Both databases are reachable, redo transport and apply are healthy, and the standby has caught up. The DBA uses Data Guard Broker and must minimize risk to client services by completing a planned transition rather than activating a standby after an outage. What should the DBA do?

Correct Answer: B. Use DGMGRL to issue SWITCHOVER TO for the standby after verifying readiness, then confirm the new broker configuration status.
Explanation:

A switchover is the planned, reversible role transition for a healthy and synchronized configuration. Broker's SWITCHOVER command coordinates the roles and performs the transition without the data-loss implications associated with failover. A failover is intended for loss or unavailability of the primary and may require subsequent reinstatement. Opening the standby read/write and manually copying transactions is not a valid role-transition procedure. Disabling the broker and changing role parameters manually adds risk and bypasses coordinated management.

Question 12

New Single answer

Topic: Using Flashback Database in a Data Guard Configuration

Skill tested: Uses flashback capability to reinstate a former primary after a fast-start failover.

A company has fast-start failover configured and experiences a primary-site outage. The standby becomes the new primary. The original primary later returns, and its datafiles are intact, but it has diverged from the new primary. The organization configured sufficient Flashback Database retention before the incident and wants to avoid restoring a full backup. Which recovery path should the DBA pursue?

Correct Answer: C. Flash back the original primary to an appropriate point before the failover, then reinstate it as a standby under broker management.
Explanation:

Flashback Database can return the failed-over former primary to a point before it diverged, allowing broker-managed reinstatement as a standby without a full database restore, when the required flashback data is available. Opening with RESETLOGS does not reconcile the databases or convert the former primary to a standby. Converting the new primary to a snapshot standby would undermine the current primary role and does not repair the old one. A control-file copy cannot reconcile divergent datafiles, and two independent primary databases would not constitute a synchronized Data Guard configuration.

Question 13

New Multiple answers

Topic: Enabling Fast-Start Failover

Skill tested: Configures observer placement and validates the primary reinstatement path for fast-start failover.

A global organization plans fast-start failover between two data centers. It wants the observer to distinguish a primary outage from loss of connectivity to only one site, and it wants the former primary to be returned to the configuration without a full restore when possible. The DBA has broker-managed databases and Flashback Database available, but has not yet deployed the observer. Which two actions are appropriate? Select two.

Correct Answer: B. Place the observer where it can maintain independent network connectivity to the primary and standby, reducing the chance that a single-site network partition is mistaken for a primary failure.; C. Configure Flashback Database on the databases with sufficient retention so the former primary can be reinstated after failover when the required flashback point remains available.
Explanation:

An observer with connectivity independent of either database site has a better basis for distinguishing a database failure from a network partition and is less exposed to the primary site's failure. Flashback Database with adequate retention supports reinstating the former primary after failover when it can be flashed back to the appropriate point. Running the observer on the primary host shares its failure domain. Fast-start failover is broker-managed, not an independent observer-only mechanism, and standby redo logs remain important for redo transport and apply.