Question 1

What must the project team do regardless of building type for Energy and Atmosphere Prerequisite, Minimum Energy Performance?

Correct Answer: C. Establish an ENERGY STAR Portfolio Manager profile
Explanation:

For the Energy and Atmosphere Prerequisite, Minimum Energy Performance, the project team must establish an ENERGY STAR Portfolio Manager profile. This is a requirement for all building types to benchmark energy performance and track improvements over time.


Regardless of the building type, for the Energy and Atmosphere Prerequisite, Minimum Energy Performance, the project team must establish an ENERGY STAR Portfolio Manager profile. This platform is used to benchmark the building's energy performance against similar buildings and track energy consumption over time. The ENERGY STAR Portfolio Manager is a critical tool for understanding and improving a building's energy efficiency, serving as a standardized framework for measuring and reporting energy use.

Reference: This requirement is highlighted in the LEED AP Operations + Maintenance reference guide, particularly in the section covering the Energy and Atmosphere Prerequisite, Minimum Energy Performance. The guide outlines the steps for setting up an ENERGY STAR Portfolio Manager profile and its importance in the LEED certification process.

Question 2

Which of the following standards is applicable in order to comply with Indoor Environmental Quality Credit, Thermal Comfort?

Correct Answer: B. ASHRAE 55-2010
Explanation:

ASHRAE 55-2010 is the standard applicable for compliance with the Indoor Environmental Quality Credit, Thermal Comfort. This standard outlines the conditions for acceptable thermal environments and is used for the design, evaluation, and operation of buildings to meet thermal comfort requirements.


Question 3

A 1,500 ft2 (139 m2) mobile home is built in the downtown area of a major city. 90% of the project's gross floor will be

completed by the time of occupancy. LEED certification is being sought. Which rating system would be the most

appropriate one to use?

Correct Answer: C. LEED for Homes
Explanation:

For a mobile home, especially one built in a major city, the most appropriate LEED rating system to use would be LEED for Homes. This is because ASHRAE 90.1 and associated LEED rating systems typically exclude low-rise residential buildings, which include single-family houses, multifamily structures of three stories or fewer above grade, and manufactured houses (modular or mobile homes). Since the mobile home in question falls under the category of manufactured houses, it would be more fitting to pursue LEED for Homes certification, which is designed to cater to residential projects. Reference: Information derived from the ASHRAE 90.1-2013 User's Manual indicates the exclusion of low-rise residential buildings, including manufactured houses, from the standard's scope .


Question 4

Question 5

The maximum number of points in the Innovation Category that can be achieved by exemplary performance is

Correct Answer: B. two points
Explanation:

The maximum number of points that can be achieved by exemplary performance in the Innovation Category is two.Exemplary performance credits are a part of the Innovation in Design category and are awarded for achieving double the credit requirements or the next incremental percentage threshold1.However, it's important to note that while there are multiple strategies for earning innovation points, there are limits to how many points can be earned for each type of strategy2.


In the LEED AP Operations + Maintenance rating system, the Innovation category allows projects to earn points for employing innovative strategies that demonstrate quantifiable environmental benefits beyond what is covered by the standard LEED credits. Projects can earn points in this category through innovative performance strategies, LEED Pilot Credits, or by having a LEED Accredited Professional on the team.

Exemplary performance refers to achieving performance that significantly exceeds the requirements of existing LEED credits. However, within the Innovation category, there is a limit to the number of points that can be achieved through exemplary performance. Specifically, a project can earn a maximum of two points for exemplary performance under the Innovation category. This encourages projects to explore a range of innovative strategies while also maintaining a balanced approach to sustainability across all categories.

Reference: The LEED v4 for Building Operations and Maintenance reference guide provides detailed information on the Innovation category, including the criteria for earning points through innovative strategies, the use of Pilot Credits, and the role of a LEED Accredited Professional. It also specifies the limit on points achievable through exemplary performance, reinforcing the comprehensive approach to sustainability encouraged by the LEED rating system.

Question 6

Presuming all water fixtures meet the LEED Operations and Maintenance Rating System requirements, which of the following statements is correct when considering baseline water usage in relation to water use?

Correct Answer: B. For a building with a certificate of occupancy dated 1995 or later, the baseline water usage is 120% of the water use
Explanation:

In relation to the baseline water usage for buildings with respect to their certificate of occupancy dates, for buildings dated 1995 or later, the baseline is set at 120% of the water use that would result if all fixtures met the code requirements. This guideline is part of the LEED Operations and Maintenance Rating System's approach to evaluating water use in buildings and setting a baseline for comparison and improvement. Reference: LEED v5 O+M: Existing Buildings beta version


Question 7

At a minimum, how often should a survey of building occupants be conducted about transportation patterns according to the Location and Transportation Credit, Alternative Transportation, Option 1?

Correct Answer: A. Five years
Explanation:

The LEED AP O+M V4.1 requires a survey of building occupants regarding transportation patterns to be conducted at a minimum every five years. This is to ensure that the data on alternative transportation usage remains current and accurate for the Location and Transportation Credit, Alternative Transportation, Option 1.


Question 8

To determine possible credit compliance for Energy and Atmosphere Credit, Advanced Energy Metering, what information needs to be verified?

Question 9

What is the diversion percentage of ongoing consumables in order to achieve exemplary performance as specified in Materials and Resources Credit, Solid Waste Management - Ongoing?

Correct Answer: D. 90%
Explanation:

To achieve exemplary performance in the Materials and Resources Credit, Solid Waste Management - Ongoing, a diversion percentage of 90% for ongoing consumables is required. This high level of diversion demonstrates an advanced commitment to reducing waste and promoting recycling and composting. By diverting 90% of ongoing consumables from the landfill, projects significantly contribute to sustainability goals by minimizing their environmental footprint related to waste.

Reference: The LEED AP Operations + Maintenance reference guide specifies the criteria for exemplary performance in waste management, including the 90% diversion target. This ambitious goal underscores the importance of comprehensive waste reduction strategies in LEED-certified projects.


Question 10

According to Sustainable Sites Credit, Rainwater Management, what is the maximum time allowed to comply with a failed inspection?

Correct Answer: C. 60 days
Explanation:

According to the Sustainable Sites Credit, Rainwater Management, the maximum time allowed to comply with a failed inspection is 60 days. This timeframe is given to the project team to address and rectify any issues found during an inspection related to rainwater management strategies implemented in the project. This requirement ensures timely resolution of problems to maintain the effectiveness of rainwater management practices.


Question 11

How many months of metered energy use after occupancy are required to earn Energy and Atmosphere Prerequisite, Minimum Energy Performance?

Correct Answer: C. 12 months
Explanation:

The Energy and Atmosphere Prerequisite, Minimum Energy Performance requires 12 months of metered energy use data after occupancy. This duration is necessary to provide a comprehensive view of the building's energy consumption patterns throughout the different seasons of the year.


To fulfill the Energy and Atmosphere Prerequisite, Minimum Energy Performance, LEED requires a building to demonstrate energy use through 12 months of metered energy data post-occupancy. This duration ensures that a full annual cycle is considered, accounting for seasonal variations in energy consumption. The data collected over this period provides a comprehensive overview of the building's energy performance, enabling accurate benchmarking against LEED standards and identifying opportunities for energy efficiency improvements.

Reference: This requirement is specified in the LEED AP Operations + Maintenance reference guide, under the section detailing the Energy and Atmosphere Prerequisite, Minimum Energy Performance. The guide explains the rationale behind the 12-month period and how it contributes to a reliable assessment of the building's energy use.

Question 12

What is the maximum number of points a project could achieve using innovation credits for the Innovation Credit, Innovation?

Question 13

Which of the following prerequisites or credits have synergies with Materials and Resources Prerequisite, Facility Maintenance and Renovation Policy?

Correct Answer: D. Indoor Environmental Quality Credit, Indoor Air Quality Management Program
Explanation:

There are synergies between the Materials and Resources Prerequisite, Facility Maintenance and Renovation Policy, and the Indoor Environmental Quality Credit, Indoor Air Quality Management Program. Both focus on maintaining high environmental and health standards within the building, with the former emphasizing sustainable maintenance and renovation practices, and the latter concentrating on maintaining optimal indoor air quality through proper management and practices.

Reference: The interconnectedness of these prerequisites and credits is discussed in the LEED AP Operations + Maintenance documentation, highlighting how sustainable maintenance and renovation practices directly contribute to better indoor air quality, thereby supporting the objectives of the Indoor Air Quality Management Program.


Question 14

A building manager changes the sequence of operation for boilers to better match heating demand as a result of an ASHRAE Level 2 analysis. Which of the following is an example of an appropriate topic for training of building operations staff to continue implementation of this change and meet the requirements of Energy and Atmosphere Credit, Existing Building Commissioning - Implementation?

Correct Answer: D. Operating schedules and requirements
Explanation:

Training building operations staff on operating schedules and requirements is appropriate when implementing changes in the sequence of operation for boilers. This ensures that the staff can effectively manage the new operating sequence to match heating demand, as identified by the ASHRAE Level 2 analysis.


After implementing changes in the sequence of operation for boilers based on an ASHRAE Level 2 analysis, an appropriate topic for training building operations staff is operating schedules and requirements. This training ensures that staff understand and can effectively implement the new operating procedures, maintaining the improved efficiency and performance of the boilers.

Question 15

A project is pursuing Materials and Resources Credit, Solid Waste Management - Facility Maintenance and Renovation. The project has generated the following waste as part of their Facility Maintenance and Renovation activities: 2,000 lbs. (907.2 kg) of steel, 900 lbs. (408.2 kg) of carpet, 1,100 lbs. (498.9 kg) of wood, and 1,500 lbs.

(680.4 kg) of wallboard. If the project has diverted 1,800 lbs. (816.4 kg) of steel, 900 lbs. (408.2 kg) of carpet, 1,000 lbs. (453.6 kg) of wood, and 250 lbs. (113.3 kg) of wallboard, what is the actual diversion rate achieved?

Correct Answer: B. 71.8% of diversion
Explanation:

The actual diversion rate is calculated by dividing the total weight of the diverted waste by the total weight of the generated waste. In this case, the project generated 2,000 lbs. of steel, 900 lbs. of carpet, 1,100 lbs. of wood, and 1,500 lbs. of wallboard, making a total of 5,500 lbs. of waste. The project diverted 1,800 lbs. of steel, 900 lbs. of carpet, 1,000 lbs. of wood, and 250 lbs. of wallboard, making a total of 3,950 lbs. of waste. Therefore, the actual diversion rate achieved is approximately 71.8%.