Limited-Time Offer: Enjoy 50% Savings! Ends in 00h 00m 00s Coupon code: 50OFF
Skip to content

Free NetApp Implementation Engineer - SAN ONTAP NS0-522 Exam Questions

Page: 1 / 11 Total 107 questions

Want more questions? Get Premium Access.

Question 1

An administrator has a two-node NetApp ONTAP cluster that is hosting FC LUNs for 90 SAN hosts. The hosts are experiencing occasional performance problems and receiving QFULL responses from the cluster nodes.

Which action would resolve this issue?

Correct Answer: D. Configure additional FC target ports.
Explanation:

A QFULL response indicates that the storage controller's FC target-port command queue has reached its supported capacity and cannot accept additional SCSI commands. With 90 hosts generating I/O, excessive fan-in to the existing target ports can exhaust available queue resources. Configuring additional FC target ports allows host connections and queued commands to be distributed across more storage-side target resources, reducing pressure on each individual target port. Increasing initiator queue depth would worsen the condition because hosts could submit more outstanding commands. Similarly, increasing target-port queue depth is not the appropriate administrator-controlled remedy presented here because the physical target adapter has defined queue limits. NetApp recommends planning host fan-in carefully to avoid QFULL conditions. Relevant topics include FC queue depth, target-port fan-in, QFULL responses, SAN scalability, and FC target-port design


Question 2

An SVM is created for FCP traffic. LUNs must be created to share with ESXi hosts for datastores. Which two items must be configured after the LUN is created, for this to happen? (Choose two.)

Correct Answer: A. Create an igroup with the ESXi hosts' WWPNs.; D. Map the LUNs to the igroup.
Explanation:

For configuring LUNs to share with ESXi hosts for datastores in an SVM created for FCP traffic, the following steps are necessary after creating the LUN:

Create an igroup with the ESXi hosts' WWPNs: This step involves defining an initiator group that includes the WWPNs of the ESXi hosts that need access to the LUN.

Map the LUNs to the igroup: This step assigns the LUN to the created igroup, allowing the ESXi hosts to access the LUN.

For further details, refer to:

NetApp Documentation on LUN and igroup Configuration


Question 3

After a storage administrator creates a LUN using the CLI, the LUN does not appear on the corresponding host.

What should be done to correct this issue?

Correct Answer: B. Map the LUN.
Explanation:

A LUN created with the ONTAP CLI is not automatically visible to a host merely because the storage object exists. For FCP or iSCSI access, ONTAP must associate the LUN with an initiator group by creating a LUN mapping. NetApp's SAN provisioning workflow explicitly creates the LUN, creates or identifies the igroup containing the host initiators, and then maps the LUN to that igroup. The mapping assigns host access and a LUN ID that the initiator uses to discover the device. Bringing the LUN online does not grant host access, mounting a volume is not part of SAN LUN presentation, and export policies apply to NAS protocols rather than FCP/iSCSI LUN access. Relevant SAN ONTAP topics are LUN provisioning, igroups, LUN mapping, LUN IDs, and host discovery.


Question 4

A storage engineer zones a new FCP SVM to an SQL cluster.

Which two commands can be used to check connectivity? (Choose two.)

Correct Answer: C. vserver fcp ping-igroup show; D. vserver fcp ping-initiator show
Explanation:

ONTAP provides dedicated FCP connectivity tests for validating communication between host initiators and FC LIFs. The vserver fcp ping-igroup show command performs a connectivity check between FCP initiators contained in an igroup and the FCP LIFs through which those initiators are configured to connect. The vserver fcp ping-initiator show command performs the equivalent validation for an individual FC initiator. These commands are therefore appropriate after zoning a new FCP SVM to SQL hosts. cluster ping-cluster validates ONTAP's internal cluster network and is unrelated to host-to-storage FC connectivity. network fcp zone show displays discovered FC zoning information but is not the specific FCP initiator connectivity test requested. Relevant SAN ONTAP topics include FC zoning validation, igroups, WWPN connectivity, FCP LIFs, and SAN troubleshooting commands.


Question 5

A customer has a two-node NetApp ONTAP cluster that Is hosting FC LUNs for 64 SAN hosts. An administrator is tasked to add 40 more hosts to the environment.

What two actions would the administrator need to take to avoid potential performance problems with the environment? (Choose two.)

Correct Answer: B. Configure additional FC target ports.; C. Configure additional SAN LIFs.
Explanation:

When adding 40 more hosts to a two-node NetApp ONTAP cluster that is already hosting 64 SAN hosts, the following actions are necessary to avoid potential performance problems:

Configure additional FC target ports: Increasing the number of Fibre Channel (FC) target ports on the storage nodes will help distribute the I/O load more evenly, reducing the risk of bottlenecks.

Configure additional SAN LIFs: Adding more SAN Logical Interfaces (LIFs) will ensure that the increased number of hosts can connect efficiently, improving load balancing and path management.

These actions help maintain optimal performance and prevent congestion in the SAN environment.

For more detailed guidance, refer to:

NetApp SAN Host Configuration Overview

NetApp Best Practices for SAN (NetApp) (NetApp)


Question 6

A customer asks for help cloning one database LUN from a SnapMlrror destination volume for testing the data with a new application.

What command should the administrator use to clone the LUN?

Correct Answer: C. volume clone create
Explanation:

To clone a LUN from a SnapMirror destination volume for testing purposes, the volume clone create command should be used. This command creates a FlexClone volume from the SnapMirror destination, making the LUN within it accessible for testing without disrupting the original volume.

For more details, refer to:

NetApp Documentation on Volume Clone Create

NetApp Community Discussion on LUN Cloning


Question 7

What Is a recommended setting for using the NetApp ONTAP LUN fractional reserve?

Correct Answer: C. Space guarantee is set to volume.
Explanation:

The recommended setting for using the NetApp ONTAP LUN fractional reserve is to set the space guarantee to 'volume'. This setting ensures that the required space for overwrites in the volume is reserved, preventing potential write failures when snapshot copies are created. This setup helps in maintaining the performance and reliability of the storage system by ensuring there is always enough space allocated for the LUN.

For further details, you can refer to:

NetApp Community Discussion on Fractional Reserve

NetApp Documentation on Space Management


Question 8

What is the minimum number of rack units that are required on each site for a NetApp AFF All San Array (ASA) A800 MetroCluster IP configuration with 72 disks per site and Cisco N9K-C9336C-FX2 backend switches?

Correct Answer: A. 16 RU
Explanation:

For a NetApp AFF All SAN Array (ASA) A800 MetroCluster IP configuration with 72 disks per site and Cisco N9K-C9336C-FX2 backend switches, the minimum number of rack units required on each site is 16 RU. This includes space for the controllers, disk shelves, and the necessary network switches. This configuration ensures that all components are properly accommodated and operational within the specified rack space.

For detailed information on the rack unit requirements and MetroCluster IP configurations, refer to:

NetApp Documentation on MetroCluster IP

MetroCluster IP Solution Architecture


Question 9

An engineer has just installed a new MetroCluster IP system for their SAN environment and wants to verify if all backend network connections are set up and working correctly.

Which two commands must the engineer run to verify the configuration? (Choose two.)

Correct Answer: A. metrocluster check run; B. metrocluster check connection show
Explanation:

The engineer should first execute metrocluster check run to perform a current diagnostic validation of the MetroCluster configuration. NetApp documents that this command checks MetroCluster components and relationships and records any configuration errors. After the diagnostic completes, metrocluster check connection show displays the connection-specific results for MetroCluster IP nodes, including network connectivity checks and error information relating to ping, MTU, and storage connectivity. This directly addresses the requirement to verify backend network connections. metrocluster check cluster show focuses on cluster configuration results, while metrocluster check lif show focuses on LIF placement and related checks rather than the backend connections themselves. Relevant SAN ONTAP and MetroCluster topics include MetroCluster diagnostics, backend IP connectivity, configuration validation, inter-site connections, and post-installation verification.


Question 10

A storage administrator wants to increase security and optimize performance in a recently implemented SAN deployment.

What should the storage administrator configure to ensure initiator restriction to certain LIFs?

Correct Answer: D. Access list
Explanation:

To increase security and optimize performance in a SAN deployment, configuring an access list is essential. Access lists restrict initiator access to specific LIFs, ensuring that only authorized hosts can connect to the storage system. This helps in enhancing security by preventing unauthorized access and optimizes performance by controlling and managing the paths used for storage access.

For additional details, you can refer to:

NetApp SAN Administration Guide