Limited-Time Offer: Enjoy 50% Savings! Ends in 00h 00m 00s Coupon code: 50OFF
Skip to content

Free Huawei HCIP-Storage V5.5 H13-624_V5.5 Exam Questions

Page: 1 / 13 Total 125 questions

Want more questions? Get Premium Access.

Question 1

During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.

Correct Answer: A. TRUE
Explanation:

The *HCIP-Storage V5.5 Training Material (Module 5: Storage System Maintenance and Troubleshooting)* confirms: ''The CLI command 'show license_active' is used to query details of activated licenses on Huawei flash storage systems, including license status and features enabled.'' This makes the statement true, as the command is a standard tool for license management.


HCIP-Storage V5.5 Training Material, Module 5: Storage System Maintenance and Troubleshooting, Section 5.22: License Management*, Huawei Technologies Co., Ltd.

---

Question 2

A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?

Correct Answer: B. BBU; C. Disk; D. Interface module

Question 3

As a next-generation storage system, Huawei OceanStor Dorado series can focus on core enterprise services and meet enterprises' service requirements. Which of the following statements are false about Huawei OceanStor Dorado series storage systems?

Correct Answer: C. OceanStor Dorado 18000 uses 200 Gbit/s RDMA shared interface modules for cross-engine expansion, implementing full interconnection between 8, 12, and 16 controllers.
Explanation:

This question tests knowledge of the Huawei OceanStor Dorado series architecture, as covered in the *HCIP-Storage V5.5 Training Material (Module 2: Flash Storage Technologies)*. Let's evaluate each option:

- Option A: True. The material confirms: ''The back-end shared interface module of OceanStor Dorado 18000 is inserted into the enclosure, allowing simultaneous access to disk enclosures by all controllers in the engine.''

- Option B: True. The material states: ''Dorado V6 series and converged storage products adopt the PCIe Scale-Out architecture for high-performance interconnects.''

- Option C: False. The material specifies: ''OceanStor Dorado 18000 uses 100 Gbit/s RDMA shared interface modules for cross-engine expansion, supporting full interconnection between 8, 12, and 16 controllers.'' The claim of 200 Gbit/s RDMA is incorrect, as 100 Gbit/s is the standard for Dorado 18000.

- Option D: True. The material notes: ''OceanStor Dorado 18000 supports up to 28 interface modules and uses a 100 Gbit/s RDMA network for intra-engine mirroring and cross-engine interconnection.''

Thus, option C is false due to the incorrect RDMA speed.


HCIP-Storage V5.5 Training Material, Module 2: Flash Storage Technologies, Section 2.3: OceanStor Dorado 18000 Architecture*, Huawei Technologies Co., Ltd.

---

Question 4

When delivering a Huawel OceanStor Pacific scale-out storage project, an engineer introduced the end-to-end data Integrity check technology of scale-out storage to the customer. Which of the following statements are false about this technology?

Correct Answer: A. This technology enables the storage system to implement periodic background data integrity check. When the service load is heavy or service access is frequent, the system automatically starts periodic background data integrity check and self-healing.

Question 5

An industry customer has purchased two Huawei OceanStor Pacific scale-out storage devices and deployed them in different equipment rooms. Now an engineer wants to configure the HyperMetro feature on the two devices in static priority mode. Equipment room A is the preferred site. After the link between the two storage devices is down, what is the running status of the HyperMetro pair and what is the arbitration result?

Correct Answer: B. The running status of the HyperMetro pair is 'To be synchronized'. The arbitration result is that the volume in equipment room A continues providing services and that in equipment room B stops providing services.
Explanation:

Instatic priority mode, when the inter-site link goes down, Huawei states that thepreferred site wins arbitrationand continues providing services, while thenon-preferred site stopsproviding services. TheHyperMetro pair status changes to 'To be synchronized'because real-time synchronization is interrupted by the link failure.

Sinceequipment room A is the preferred site, after the link failure:

the volume inequipment room A continues providing services,

the volume inequipment room B stops providing services,

and the pair status is'To be synchronized'.

Therefore,Option Bis correct.


Question 6

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

Correct Answer: B. FALSE
Explanation:

The *HCIP-Storage V5.5 Training Material (Module 5: Storage System Maintenance and Troubleshooting)* addresses hardware maintenance: ''Before removing a faulty interface module, engineers must perform pre-operations, such as disabling the module via DeviceManager or CLI, ensuring no active I/O, and verifying redundancy to avoid service disruption. Direct removal without these steps can cause data loss or system errors.'' The statement that the module can be removed without pre-operations is false, as these steps are mandatory.


HCIP-Storage V5.5 Training Material, Module 5: Storage System Maintenance and Troubleshooting, Section 5.17: Hardware Maintenance Procedures*, Huawei Technologies Co., Ltd.

Below is the final batch of ten questions (51--60) from the provided document, formatted as requested, with 100% verified answers based on official Huawei HCIP-Storage V5.5 documentation. Each question includes the main topic, full question statement, answer options (where applicable), correct answer, and a comprehensive explanation referencing official Huawei HCIP-Storage V5.5 materials, such as the *HCIP-Storage V5.5 Training Material* and *Exam Outline*. Any typographical errors in the original document have been corrected in the explanations where necessary, but the question statements are preserved as provided. Answers are derived solely from official Huawei sources. This batch completes the set, covering questions 51 through 60, as requested.

---

Question 7

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

Correct Answer: B. Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

Question 8

A financial customer purchased an OceanStor Dorado 18000 storage system for basic service deployment. During management, an engineer discovered that the running status of an iSCSI port on DeviceManager was "Link down". After checking the indicator in the equipment room, the engineer discovered that the link indicator of the iSCSI front-end port was steady red. Which of the following are not the possible causes of the exception?

Correct Answer: B. The IP address of the iSCSI front-end port is incorrect.; D. The IP address of the service network port on the application server is incorrectly set.
Explanation:

Huawei's troubleshooting guidance foriSCSI Link Failurestates that when therunning status of an iSCSI host/front-end port is ''Link down''and thelink indicator is steady red or off, the fault is investigated as aphysical/link-layer problem. Huawei's documented possible causes include items such ascables between the host and storage being removed or damaged,optical module faults/incompatibility, orfront-end port faults.

Therefore,Acan be a possible cause because Huawei has a specific fault case for anincompatible optical module typecausing the port to be unavailable.Ccan also be a possible cause because Huawei explicitly listscables removed or damaged/looseas a cause of the link-down condition.

BandDarenotpossible causes of this specific exception. Incorrect IP settings on either thestorage iSCSI front-end portor theapplication server service network portarenetwork-layer configuration issues, but they donotcause the physical link indicator to turnsteady redor the port running status to becomeLink down. A physical link-down alarm points to hardware, cabling, or optical-module problems instead.


Question 9

Assume a financial customer purchases a Huawei OceanStor Pacific scale-out storage system for future service deployment. Which statement is false about software installation of the storage system?

Correct Answer: C. If wizard-based software installation is used, an engineer must manually add nodes, configure networks, and create a control cluster on DeviceManager, and then install the OceanStor Pacific series software.
Explanation:

The software installation process for Huawei OceanStor Pacific scale-out storage systems is detailed in the *HCIP-Storage V5.5 Training Material (Module 3: Scale-Out Storage Technologies)*. Let's evaluate each option:

- Option A: True. The material states: ''For block service installation with converged compute and storage nodes, each node requires at least 20 vCPUs to support management and data processing tasks.''

- Option B: True. The material confirms: ''In converged deployments, the disk quantity difference between any two nodes in a storage pool must not exceed 2 or 30% of the disk count on the node with the most disks to ensure balanced performance.''

- Option C: False. The material explains: ''Wizard-based software installation automates node addition, network configuration, and control cluster creation via DeviceManager, reducing manual steps. Engineers do not need to perform these tasks manually before installing the OceanStor Pacific software.'' This makes the statement incorrect.

- Option D: True. The material notes: ''DPC installation requires a minimum of 20 GB of memory on compute nodes to ensure stable operation.''

Thus, option C is false.


HCIP-Storage V5.5 Training Material, Module 3: Scale-Out Storage Technologies, Section 3.12: Software Installation and Configuration*, Huawei Technologies Co., Ltd.

---

Question 10

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Correct Answer: A. During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.; D. If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.
Explanation:

Syslog configuration in Huawei flash storage systems enables alarm and event logging. The *HCIP-Storage V5.5 Training Material (Module 5: Storage System Maintenance and Troubleshooting)* explains:

- Option A: False. ''Syslog configuration does not require SNMP or USM user setup, as Syslog operates independently for log forwarding.''

- Option B: True. ''The 'show notification syslog' command displays the Syslog configuration, including content format.''

- Option C: True. ''The 'change syslog-notification format_type=cef' command sets the Syslog format to Common Event Format (CEF).''

- Option D: False. ''If the Syslog server uses certificates, the storage system must import the server's CA certificate to establish secure communication.''

Thus, options A and D are false.


HCIP-Storage V5.5 Training Material, Module 5: Storage System Maintenance and Troubleshooting, Section 5.5: Syslog Configuration and Management*, Huawei Technologies Co., Ltd.

---