Limited-Time Offer: Enjoy 50% Savings! Coupon code: 50OFF Use it at checkout
Skip to content

Free Pegasystems Pega Certified Robotics System Architect (PCRSA) 80V1 2019 PEGAPCRSA80V1_2019 Exam Questions

Last updated: · 15 practice questions with answers and explanations

Page: 1 / 6 Total 60 questions

Want more questions? Get Premium Access.

Question 1

New Single answer

Topic: Project Management

Skill tested: Select project documentation that defines solution requirements and architecture responsibilities.

A delivery team is beginning a robotic solution for a claims department. Business analysts have documented workflows, exception cases, and expected outcomes, while the technical team must decide how the solution will be divided into projects and how those projects will interact. The client wants reviewable decisions before development begins and needs a clear record of both business scope and technical structure. Which documentation approach best meets these needs?

Correct Answer: B. Use the Solution Design Document to capture the solution requirements and process design, and the Solution Architecture Document to describe the technical structure and integration approach.
Explanation:

The Solution Design Document communicates the intended business solution, including processes and requirements. The Solution Architecture Document records how the solution is technically organized, including project structure and integration considerations. Keeping these artifacts distinct gives business and technical stakeholders the appropriate basis for review before implementation. Reversing their roles obscures the intended audience and purpose; logs capture runtime activity, not requirements or architecture, and a deployment package is not a substitute for design decisions.

Question 2

New Single answer

Topic: System Integration

Skill tested: Choose an adapter type and configuration approach appropriate to a target application.

A service desk team needs an automation to interact with a legacy Windows desktop client and a separate browser-based application. The desktop client is a conventional Windows application, while the browser application uses standard web controls and must be interrogated through browser-aware matching. The team wants both applications represented as adapters in the solution rather than relying on screen coordinates. Which configuration is the most appropriate starting point?

Correct Answer: A. Create a Windows adapter for the desktop client and a Web adapter for the browser application, then configure each adapter for its target application.
Explanation:

A Windows adapter is intended for Windows desktop applications, while a Web adapter provides browser-oriented interaction with web applications. Configuring separate adapters preserves the appropriate interrogation and matching model for each target. Treating the browser process as a Windows application ignores web-specific controls; web matching cannot represent a conventional desktop client; and a Universal Web adapter does not replace the Windows adapter for a non-web application.

Question 3

New Single answer

Topic: Interrogation

Skill tested: Use Select Element to identify a specific web control when standard selection is ambiguous.

A web application presents a list of customer records with several identical buttons labeled "Open." Standard interrogation selects the first matching button, but the automation must open the record whose row contains a specified customer identifier. The page structure is stable enough to identify the row and its child control, and the team wants a specific control rather than a broad page-level match. What should the developer do?

Correct Answer: C. Use Select Element to locate the required row or button based on the customer identifier and create the control from that selection.
Explanation:

Select Element is appropriate when standard selection is ambiguous and the developer needs to identify a particular element in the page context. Selecting the row or its child button using the customer identifier gives the control a meaningful association with the intended record. Changing a button's title rule to a value it does not possess is not a valid identification strategy. A global page does not distinguish repeated controls within a page, and screen-position matching abandons the web control model.

Question 4

New Single answer

Topic: Interrogation

Skill tested: Improve web control identification by selecting stable, discriminating match rules.

After a browser update, an automation intermittently binds to the wrong navigation link. The existing match rules rely on a generated identifier that changes between sessions, while several links share the same tag and displayed text. The application team confirms that the link's stable accessible name and its containing page title are consistent. Which change is the best match-rule practice?

Correct Answer: B. Use stable identifying attributes, such as the accessible name, together with suitable page context, and remove rules that are dynamic or non-discriminating.
Explanation:

Reliable match rules use properties that remain stable and distinguish the intended control. Here the accessible name and page title are known to be consistent, so they provide a better basis for matching than a generated identifier. Adding every property can make matching brittle when incidental properties change, while a shared tag or text alone may not discriminate among links. Coordinates are sensitive to layout changes and do not provide robust web-control identification.

Question 5

New Single answer

Topic: Debugging and Diagnostics

Skill tested: Use automation playback and runtime values to isolate a failing automation step.

An automation completes successfully in development but fails in a user session after a dialog appears. The team has a recorded playback and a diagnostic log from the failing run. The failure occurs before the next application action, and the developer must determine whether the automation received the expected dialog result or whether the control failed to match. What is the most effective first investigation?

Correct Answer: A. Use playback to inspect the failure point, then review the log and relevant automation values around the dialog and matching step.
Explanation:

Playback and diagnostic evidence help correlate the automation sequence, runtime values, and failure location. Inspecting them first can distinguish an unexpected dialog result from a control-match failure and guide a targeted correction. Clearing the log destroys useful evidence, while broadening all match rules can create new false matches. Adding delays without establishing a timing issue masks symptoms and may not address incorrect data or a failed control match.

Question 6

New Single answer

Topic: Debugging and Diagnostics

Skill tested: Configure diagnostic logging at the needed level and interpret generated log evidence.

A production support team is investigating an intermittent failure that cannot be reproduced on demand. Existing logs show only that the automation stopped, but do not expose the sequence of relevant operations. Logging every component at the most verbose level would create excessive files and make review difficult. The support team needs enough evidence to trace the affected automation while preserving manageable diagnostics. What is the best next action?

Correct Answer: A. Update diagnostics settings to capture the needed detail for the affected investigation, include a diagnostic log component in the relevant automation, and review and clear the resulting log after analysis.
Explanation:

A targeted diagnostics configuration and a diagnostic log component provide useful execution evidence without imposing unnecessary verbosity across the entire solution. The resulting log can be dissected to follow relevant events and then cleared according to operational practice. Permanently enabling maximum logging increases noise and storage. A deployment package contains project artifacts, not a trace of a particular failed run, and message dialogs are intrusive, incomplete, and unsuitable as a durable diagnostic mechanism.

Question 7

New Multiple answers

Topic: Automations

Skill tested: Use Object Explorer references and automation links to build maintainable application workflows.

A developer is building a workflow that reads a value from an interrogated application control, passes it to a reusable automation, and then continues only after that automation has completed. The solution should use the controls represented in Object Explorer rather than duplicate application access logic. The reusable automation must return a result to its caller, and the developer wants the control-to-automation relationship to remain clear during maintenance. Which two design choices best meet these requirements? Select two answers.

Correct Answer: B. Use an automation link that supports returning execution to the caller, and define the reusable automation's inputs and outputs for the data exchanged.; D. Reference the interrogated control through Object Explorer in the automation and use the appropriate automation link to invoke the reusable automation.
Explanation:

Object Explorer exposes the interrogated application objects that automations can reference, keeping application interaction tied to the modeled controls. An appropriate automation link invokes reusable logic, while explicit inputs and outputs establish the data contract and the return flow to the caller. A fixed literal discards live application data. Jump To is a procedure-flow mechanism, not a substitute for invoking a separate automation with a return contract. A dialog caption is not a reliable application-data interface.

Question 8

New Multiple answers

Topic: Automations

Skill tested: Apply UseKeys and RaiseEvent appropriately when interacting with application controls.

A desktop application has a text field that accepts keyboard input but does not reliably process direct value assignment. After entering a value, the application's own behavior is triggered by a control event. A developer has confirmed that the field and event are exposed by the adapter and wants the automation to use the application's normal interaction path. The automation must not simulate a mouse click at a fixed screen location. Which two actions are most appropriate? Select two answers.

Correct Answer: A. Use RaiseEvent on the relevant exposed control event after entering the value, when that event is the required application trigger.; C. Use the control's UseKeys property or keyboard-oriented interaction to send the value as keystrokes.
Explanation:

UseKeys is appropriate when the target control must receive keyboard input rather than merely have a value assigned. If application behavior depends on a specific exposed event, RaiseEvent can invoke that event through the control rather than relying on screen coordinates. Direct property assignment may not reproduce keyboard or event-driven behavior. Jump To changes automation flow, not application state, and a delay cannot trigger the required application event.

Question 9

New Single answer

Topic: Automations

Skill tested: Control automation flow with labels, Jump To, decisions, and bounded looping logic.

A reconciliation automation processes a changing number of rows and must retry a row once when the application temporarily rejects it. The developer has placed the row-processing logic in a procedure and uses labels and Jump To components for flow control. Unbounded retries are prohibited because a failed row must not stall the batch. Which design best satisfies the requirement?

Correct Answer: C. Use a decision to check row status and retry count, jump to the retry label only when the count permits, and advance or report failure when the limit is reached.
Explanation:

A decision combined with explicit retry state and a bounded Jump To path implements the required one-retry policy while guaranteeing progress. The automation can proceed to the next row or report the failure after the limit. An unconditional jump can create an infinite loop, and a fixed iteration count does not correctly reflect a changing row set. Waiting may help with timing, but it neither limits retries nor resolves a persistent application rejection.

Question 10

New Single answer

Topic: Automations

Skill tested: Extract application data through proxies and process records with appropriate automation logic.

A team needs to process customer values returned from an application without hard-coding control properties throughout the workflow. The values are represented by an application data proxy, and the automation must validate each value before writing a summary to a file. The number of returned values can vary per run. Which approach is most appropriate?

Correct Answer: D. Use the data proxy to access the returned application data, apply decision or expression logic to validate it, and loop over the actual collection before using file utilities.
Explanation:

A data proxy provides access to application data in a form that can be extracted and used by automation logic. Applying decisions or expressions and iterating over the actual returned collection supports variable result counts; file utilities can then produce the summary. Treating the proxy as an opaque string prevents validation, while fixed iteration counts and coordinates are brittle. Manual dialogs do not provide a reliable automated data-processing path.

Question 11

New Single answer

Topic: Automations

Skill tested: Configure Wait logic to synchronize automation with application readiness.

An automation intermittently attempts to select a result before the results panel is populated. Adding a long fixed delay reduced failures but slows every run, including runs where the panel loads quickly. The panel exposes a control that appears when results are ready, and the automation should continue only after that control is available. Which change is best?

Correct Answer: B. Use a wait condition tied to the results panel or its identifying control, with an appropriate timeout and failure path.
Explanation:

A condition-based wait synchronizes the automation with the application state rather than imposing the same delay on every run. A timeout and failure path prevent indefinite blocking when results never appear. Increasing a fixed delay penalizes fast runs and still cannot guarantee success beyond the chosen duration. Repeating selection without a readiness check can create an uncontrolled loop, and Jump To alone does not establish that the panel is available.

Question 12

New Multiple answers

Topic: Interaction Framework

Skill tested: Configure project references and context values for coordinated interaction between projects.

A solution is divided into a shared utility project and a business workflow project. The workflow project needs to invoke shared functionality, while the Interaction Manager must distinguish the active customer case using context values. The team wants a maintainable project-to-project relationship and context data that can be consumed consistently by participating projects. Which two actions are appropriate? Select two answers.

Correct Answer: B. Create the project-to-project reference from the workflow project to the shared utility project and use the referenced components through that relationship.; C. Define context values using a consistent structure and names that participating projects can use to identify the active case.
Explanation:

A project reference allows one project to use components from another without duplicating shared implementation. Consistently structured context values let the Interaction Framework and participating projects identify relevant session or case information. Copying components creates maintenance divergence; a local-only variable is not shared context; and automation flow labels do not establish project dependencies or cross-project context.

Question 13

New Single answer

Topic: Interaction Framework

Skill tested: Use Interaction Manager configuration and interaction.xml to coordinate application interactions.

A support solution contains multiple projects that participate in a coordinated user interaction. The team has added an Interaction Manager component but observes that the expected project interaction is not occurring. The project configuration includes an interaction.xml file, and the team must preserve the existing project boundaries while correcting the coordination setup. What should the developer do first?

Correct Answer: C. Review the interaction.xml definitions and Interaction Manager configuration together to confirm that the participating projects and their interaction behavior are represented consistently.
Explanation:

The Interaction Framework relies on coordinated configuration and component use. Reviewing interaction.xml alongside the Interaction Manager setup is the appropriate first step to find mismatches in the intended participating projects or interaction behavior. Removing the configuration assumes automatic discovery that is not the purpose of the file. A Windows adapter handles application integration, not project coordination, and collapsing project boundaries is unnecessary without evidence that the architecture is invalid.

Question 14

New Single answer

Topic: Deployment

Skill tested: Build a deployment package from project configuration and deployment properties.

A release engineer must provide a deployable package for a robotic solution containing several projects and their required references. The team has configured project deployment properties, but a local build has been used only for development and does not clearly represent the intended release artifact. The release process requires the package to reflect the configured project contents and be suitable for distribution. What is the most appropriate action?

Correct Answer: D. Create the deployment package using the configured project deployment properties and verify that the required projects and dependencies are included.
Explanation:

Deployment properties and project configuration determine the content and behavior of the release artifact. Creating a deployment package from the configured solution and verifying required projects and dependencies supports a controlled handoff. Copying only the main project risks missing referenced components. A diagnostic log records runtime evidence rather than deployable project content, and changing adapter rules on the target is not a substitute for packaging the intended solution.

Question 15

New Single answer

Topic: Deployment

Skill tested: Set project deployment properties to prepare a controlled release configuration.

A robotics team maintains development and production project configurations. A release must use the approved production settings and include the intended project configuration files, while developers must retain their development setup for continued work. The team wants to avoid manually editing files after packaging because that risks an inconsistent release. What should the team do?

Correct Answer: C. Configure the project deployment properties for the production release before creating the package, leaving development settings available for development work.
Explanation:

Preparing the project deployment properties for the intended release before packaging keeps the artifact aligned with the approved production configuration while preserving development settings. Permanently overwriting development values undermines continued development and increases configuration drift. Editing the package after creation bypasses the controlled project setup and can introduce errors. Excluding configuration files makes deployment dependent on unstated target-machine settings.